如何察看 cpu 温度 (Solaris 10 X86)

amadun
如何察看 cpu 温度 (Solaris 10 X86)

如何察看 cpu 温度 (Solaris 10 X86)

julio
温度计吧.

alex_linux
prtdiag -v for sparc

wangyl1977
回复 #3 alex_linux 的帖子

-----------好像显示不了温度哦?
System Configuration: Sun Microsystems  sun4u Sun Fire V240
System clock frequency: 167 MHZ
Memory size: 4GB        

==================================== CPUs ====================================
               E$          CPU                    CPU
CPU  Freq      Size        Implementation         Mask    Status      Location
---  --------  ----------  ---------------------  -----   ------      --------
0    1503 MHz  1MB         SUNW,UltraSPARC-IIIi    3.4    on-line     MB/P0
1    1503 MHz  1MB         SUNW,UltraSPARC-IIIi    3.4    on-line     MB/P1

================================= IO Devices =================================
Bus     Freq  Slot +      Name +
Type    MHz   Status      Path                          Model
------  ----  ----------  ----------------------------  --------------------
pci     66    MB          pci108e,1648 (network)                           
              okay        /pci@1f,700000/network@2

pci     66    MB          pci108e,1648 (network)                           
              okay        /pci@1f,700000/network

pci     33    MB          isa/su (serial)                                 
              okay        /pci@1e,600000/isa@7/serial@0,3f8

pci     33    MB          isa/su (serial)                                 
              okay        /pci@1e,600000/isa@7/serial

pci     33    MB          isa/rmc-comm-rmc_comm (seria+                    
              okay        /pci@1e,600000/isa@7/rmc-comm@0,3e8

pci     33    MB          pci10b9,5229 (ide)                              
              okay        /pci@1e,600000/ide@d

pci     66    MB          scsi-pci1000,21 (scsi-2)                        
              okay        /pci@1c,600000/scsi@2

pci     66    MB          scsi-pci1000,21 (scsi-2)                        
              okay        /pci@1c,600000/scsi@2,1

pci     66    MB          pci108e,1648 (network)                           
              okay        /pci@1d,700000/network

pci     66    MB          pci108e,1648 (network)                           
              okay        /pci@1d,700000/network

pci     66    PCI0        SUNW,qlc-pci1077,2422 (scsi-+ QLA2462            
              okay        /pci@1d,700000/SUNW,qlc@1

pci     66    PCI0        SUNW,qlc-pci1077,2422 (scsi-+ QLA2462            
              okay        /pci@1d,700000/SUNW,qlc@1,1


============================ Memory Configuration ============================
Segment Table:
-----------------------------------------------------------------------
Base Address       Size       Interleave Factor  Contains
-----------------------------------------------------------------------
0x0                1GB               1           BankIDs 0
0x200000000        2GB               1           BankIDs 1
0x1000000000       1GB               1           BankIDs 16

Bank Table:
-----------------------------------------------------------
           Physical Location
ID       ControllerID  GroupID   Size       Interleave Way
-----------------------------------------------------------
0        0             0         1GB             0
1        0             1         2GB             0
16       1             0         1GB             0

Memory Module Groups:
--------------------------------------------------
ControllerID   GroupID  Labels         Status
--------------------------------------------------
0              0        MB/P0/B0/D0   
0              0        MB/P0/B0/D1   
0              1        MB/P0/B1/D0   
0              1        MB/P0/B1/D1   
1              0        MB/P1/B0/D0   
1              0        MB/P1/B0/D1   

============================ Environmental Status ============================
Fan Status:
-------------------------------------------
Location             Sensor          Status
-------------------------------------------
F0                   RS              okay
F1                   RS              okay
F2                   RS              okay
MB/P0/F0             RS              okay
MB/P0/F1             RS              okay
MB/P1/F0             RS              okay
MB/P1/F1             RS              okay
PS0                  FF_FAN          okay         
PS1                  FF_FAN          okay         

Temperature sensors:
-----------------------------------------
Location       Sensor              Status
-----------------------------------------
MB/P0          T_CORE              okay
MB/P1          T_CORE              okay
MB             T_ENC               okay
PS0            FF_OT               okay
PS1            FF_OT               okay
------------------------------------
Current sensors:
----------------------------------------
Location             Sensor       Status
----------------------------------------
MB                   FF_SCSI      okay
PS0                  FF_OC        okay
PS1                  FF_OC        okay
------------------------------------
Voltage sensors:
-----------------------------------
Location       Sensor        Status
-----------------------------------
MB/P0          V_CORE        okay
MB/P1          V_CORE        okay
MB             V_VTT         okay
MB             V_GBE_+2V5    okay
MB             V_GBE_CORE    okay
MB             V_VCCTM       okay
MB             V_+2V5        okay
MB             V_+1V5        okay
MB/BAT         V_BAT         okay
PS0            P_PWR         okay
PS0            FF_POK        okay
PS0            FF_UV         okay
PS0            FF_OV         okay
PS1            P_PWR         okay
PS1            FF_POK        okay
PS1            FF_UV         okay
PS1            FF_OV         okay
-----------------------------------------
Keyswitch:
-----------------------------------------
Location       Keyswitch   State
-----------------------------------------
MB             SYSCTRL     NORMAL
--------------------------------------------------
Led State:
--------------------------------------------------------------
Location               Led                   State       Color
--------------------------------------------------------------
MB                     ACT                   on          green           
MB                     SERVICE               off         amber           
MB                     LOCATE                off         white           
PS0                    ACT                   on          green           
PS0                    SERVICE               off         amber           
PS0                    OK2RM                 off         blue            
PS1                    ACT                   on          green           
PS1                    SERVICE               off         amber           
PS1                    OK2RM                 off         blue            
HDD0                   SERVICE               off         amber           
HDD0                   OK2RM                 off         blue            
HDD1                   SERVICE               off         amber           
HDD1                   OK2RM                 off         blue            
HDD2                   SERVICE               off         amber           
HDD2                   OK2RM                 off         blue            
HDD3                   SERVICE               off         amber           
HDD3                   OK2RM                 off         blue            

=========================== FRU Operational Status ===========================
---------------------------------
Fru Operational Status:
---------------------------------
Location                Status
---------------------------------
MB/SC                   okay
PS0                     okay
HDD0                    present
HDD1                    present
PS1                     okay

================================ HW Revisions ================================
ASIC Revisions:
-------------------------------------------------------------------
Path                   Device           Status             Revision
-------------------------------------------------------------------
/pci@1f,700000         pci108e,a801     okay               4   
/pci@1e,600000         pci108e,a801     okay               4   
/pci@1c,600000         pci108e,a801     okay               4   
/pci@1d,700000         pci108e,a801     okay               4   

System PROM revisions:
----------------------
OBP 4.22.19 2006/09/06 23:44 Sun Fire V210/V240,Netra 210/240
OBDIAG 4.22.19 2006/09/06 23:57

Jion
楼上 SC>showenvironment

kingsu
哪有温度啊

只有 "okey"..............................
没看到具体温度啊~

yoyosys
类似不能显示温度的吧

ilinch
这个应该是机型有关系
我记得 440 prtdiag 好像能看到具体的温度
这个就看各个服务器内部是不是有相应的探针了

dreammaker
why not search previous posts?

prtpicl -v -c temperature-sensor

bbliu001
Depend on server model.

prtdiag -v for sparc

ex1. Sun V890

========================= Environmental Status =========================

System Temperatures (Celsius):
-------------------------------
Device          Temperature     Status
---------------------------------------
CPU0             62             OK
CPU1              0             OK
CPU2             76             OK
CPU3             50             OK
CPU4             55             OK
CPU5             55             OK
CPU6             55             OK
CPU7             52             OK
MB               29             OK
IOB              21             OK
DBP0             21             OK

=================================

ex2. Sun V240

Temperature sensors:
--------------------------------------------------------------------------------
Location       Sensor              Temperature  Lo   LoWarn  HiWarn   Hi  Status
--------------------------------------------------------------------------------
MB/P0          T_CORE                56C       -     -        84C     89C   okay
MB/P1          T_CORE                50C       -     -        84C     89C   okay
MB             T_ENC                 21C        -3C    5C     40C     48C   okay
PS0            FF_OT                 -         -     -       -        -     okay
PS1            FF_OT                 -         -     -       -        -     okay
--------------------------------------------------------------------------------

todaypuzzleme
x86的只能用红外线非接触式温度计测量,富士通和sun自己的小机才行

wstar
[quote]原帖由 [i]bbliu001[/i] 于 2008-6-12 03:25 发表 [url=http://bbs.chinaunix.net/redirect.php?goto=findpost&pid=8574090&ptid=1155868][img]http://bbs.chinaunix.net/images/common/back.gif[/img][/url]
Depend on server model.

prtdiag -v for sparc

ex1. Sun V890

========================= Environmental Status =========================

System Temperatures (Celsius):
------------------- ... [/quote]

这才是正解啊

yuhuohu
好像X86的在os中看不到cpu温度